How do I troubleshoot a waterlogged GIS pressure tank?

If you work in water systems, you already know how critical a properly functioning GIS pressure tank is. As a supplier of these tanks, I get at least a dozen questions every week from installers, maintenance techs, and even small building owners who notice their tank isn’t working right—and the most common complaint is that it’s waterlogged. A waterlogged tank can kill water pressure, waste energy, and even cause damage to your pump over time. After 12 years in this business, I’ve seen every possible mistake that leads to a waterlogged tank, and I want to walk you through a step-by-step troubleshooting process that’s actually based on real-world repairs, not just textbook theory. GIS Pressure Tanks

First, let’s get clear on what a properly working GIS pressure tank is supposed to do. These tanks hold a cushion of air at a set pressure (usually 2 to 5 psi lower than your pump’s cut-in pressure) separated from the water by a rubber diaphragm or bladder. When your pump kicks on, it adds water to the tank, compressing that air cushion. When the pump turns off, the compressed air pushes water back out to your taps, so you get steady pressure without the pump cycling on and off every few seconds. A waterlogged tank is when that air cushion is gone—all the space is filled with water, so the pump runs nonstop, you get weak or sputtering water, and you’re burning extra electricity because the pump never gets a chance to rest.

Before you start tearing into the tank, you need to do a quick, basic check to confirm it’s actually waterlogged. Grab a pressure gauge and hook it up to the air valve on top of the tank (that small, threaded cap you’d use to add air). If the gauge reads 0 psi or just a few psi, that’s a red flag—but don’t stop there. Turn off the main water supply to the tank, drain all the water out of it (you’ll see a drain valve at the bottom), and then check the air pressure again. If even after draining the tank, the air pressure still reads 0 or is way lower than the recommended cut-in pressure, that means air is leaking out somewhere, or the diaphragm/bladder has failed. I’ve seen so many people skip this drain step and assume the tank is bad, only to find out the air valve just has a leak.

Now, let’s break down the most common causes of a waterlogged GIS pressure tank, in the order I see them most often. The number one culprit is a broken or ruptured bladder or diaphragm. Over time, that rubber part gets stretched, wears out, or gets punctured by sediment in the water. When it breaks, water mixes with the air inside the tank, so you lose that cushion. How do you test for this? After draining the tank, blow air into the air valve at a rate of about 1 to 2 psi per second. If the air goes in easily and the pressure doesn’t hold, the bladder is probably shot. I always tell installers to check this first because replacing a bladder is way cheaper than buying a whole new tank, and it’s a fix most people can do on site in an hour.

Second most common issue is a leak in the air side of the tank. This usually happens at the air valve itself. The air valve on GIS tanks is a small Schrader-style valve, like the one on a car tire, and over time, dirt, debris, or water can get inside it, causing a slow leak. Sometimes the valve stem gets bent or breaks off. To test this, after draining the tank, add 10 to 15 psi of air and listen for a hissing sound. If you hear air escaping, first try replacing the air valve—they’re cheap (a $5 part, usually) and easy to swap. If the hiss is still there after replacing the valve, the leak could be in the welds of the tank shell, or around the connections where the tank joins the piping. That’s a bigger issue, but it’s rare compared to valve leaks.

Third, and often overlooked, is incorrect initial air pressure when the tank was installed. A lot of contractors skip the step of setting the pre-charge pressure to match the pump’s cut-in pressure, so the air cushion is too small or too big. For example, if your pump cuts in at 30 psi and cuts out at 50 psi, the tank’s pre-charge should be 28 psi—2 psi lower than cut-in, to make sure the air has enough room to compress. If someone only put 10 psi in when they installed the tank, the air will get completely compressed before the pump even kicks off, and that’s exactly what causes waterlogging. I’ve had customers call me saying their new tank is waterlogged, and it turns out the installer never checked the pressure. That’s why pre-charge pressure is non-negotiable, not just a recommendation.

Another less common but still frequent cause is sediment buildup in the tank’s water chamber. If your water has a lot of minerals (like hard water with high iron or calcium) or small particles, they can settle at the bottom of the tank and get between the diaphragm and the tank wall, or puncture the bladder. Over time, that buildup can also make the diaphragm stick, so it can’t separate air and water properly, leading to waterlogging. If you notice sediment when you drain the tank, that’s a sign you need to flush the tank regularly—we sell simple flushing kits for GIS tanks that make this easy, and I recommend doing it at least once a year, especially in hard water areas.

Now, let’s walk through the step-by-step repair process for a waterlogged GIS pressure tank, so you know exactly what to do. First, turn off all power to the pump—you don’t want it running while you’re working, that’s a safety hazard. Then, shut off the main water supply to the tank. Next, open a tap in your house to relieve pressure in the piping. Locate the drain valve at the bottom of the tank and attach a garden hose to it, run the hose to a floor drain or outside, and open the drain to empty all water from the tank. Leave the tap open while draining, that helps speed it up.

Once the tank is empty, inspect the air valve. Remove the cap, press the valve core with a screwdriver to see if air comes out—if it doesn’t, use a small tool to clean the core, sometimes dirt is blocking it. If that doesn’t work, replace the air valve. Now, test the bladder: hook a pressure gauge to the air valve, add air slowly (use a bike pump or a portable air compressor) up to your tank’s recommended pre-charge pressure (you can find this in your pump’s manual, or it’s usually 2 psi below cut-in pressure). If the pressure holds for 10 minutes, the bladder is good—you just had a bad valve or incorrect pressure. If the pressure drops, the bladder is ruptured, so you’ll need to replace it.

Replacing a bladder in a GIS tank is straightforward, but make sure you turn off the water completely and drain the tank fully first. Drain any remaining water, remove the top of the tank (most GIS tanks have a bolted top or a threaded cover), take out the old ruptured bladder, clean the inside of the tank with a mild detergent to remove sediment, then install the new bladder. Make sure the bladder is seated evenly, not twisted, before tightening the top back on. Once the bladder is in, add the correct pre-charge air pressure, slowly fill the tank with water, then turn the pump power back on, and check the pressure to make sure it’s cycling correctly.

Wait, what if the tank’s shell is rusted or corroded? I see that in older tanks, especially in areas with acidic water. If the tank has holes or cracks in the metal, the air will leak out, and there’s no way to fix that—you’ll need a new GIS pressure tank. As a supplier, I always tell customers that a good quality GIS tank should last 10 to 15 years, but if it’s more than 10 years old and already waterlogged, it’s probably time to replace it instead of throwing parts at it.

A lot of people ask me, can I just add more air to fix a waterlogged tank? The short answer is: no, not permanently. If the bladder is broken, adding more air won’t help—it’ll just push the broken diaphragm around, and the air will mix with water again. If the air valve is leaking, adding more air will just make the leak worse. Adding air is only a temporary fix, at best, and you’ll end up right back with a waterlogged tank in a few weeks. That’s a mistake I see a lot of DIYers make, so I always warn against it.

Preventing a waterlogged tank is way easier than fixing it. Here are my top tips: first, set the pre-charge pressure correctly at installation. Second, flush the tank once a year to remove sediment. Third, inspect the air valve every 6 months—just check the pressure and listen for leaks. Fourth, if you have hard water, install a water softener or a sediment filter to reduce wear on the bladder and tank.

At the end of the day, troubleshooting a GIS pressure tank doesn’t have to be complicated. It’s just about checking the most common issues first, not jumping to replace the whole tank unless you have to. As someone who’s been in the pressure tank business for more than a decade, I’ve helped thousands of people fix waterlogged tanks, and most of the time, it’s a simple fix—replace a valve, adjust the pressure, or flush sediment. If you’re still having trouble after going through these steps, or if you need a replacement tank, we’re here to help. Whether you’re a small residential installer or a commercial water system manager, we supply high-quality GIS pressure tanks designed for long-lasting performance, and our team can help you find the right size and model for your system. To discuss your needs, connect with our team to explore solutions that fit your budget and requirements.

GIS Pressure Enclosure References
Water Systems Council. (2021). Guide to Pressure Tanks for Residential and Small Commercial Systems. National Water Quality Association.
American Society of Plumbing Engineers (ASPE). (2020). Pressure Tank Maintenance and Troubleshooting Handbook.
U.S. Environmental Protection Agency (EPA). (2019). Hard Water Effects on Water System Components.


Cangzhou Jianbo Electric Power Equipment Co., Ltd.
Cangzhou Jianbo Electric Power Equipment Co., Ltd. is one of the most experienced GIS pressure tanks manufacturers and suppliers in China, featured by quality products and good service. Please rest assured to buy bulk durable GIS pressure tanks made in China here from our factory. Welcome to contact us for customized service and free sample.